If everyone goes home at 5pm then perhaps start the test then, or up to 3 hours before. So you know that if there was a problem after the test no one would be in the building and the emergency lights would have a long time to recharge overnight, before people start working again in the morning. But the building is used 24/7 365 days a year! After this full discharge test, precautions must be taken as the batteries can take up to 24 hours to recharge and so the premises should not be occupied until everything is restored. For many buildings it is possible to do this over the weekend, but for flats and other premises which are occupied full time, there will need to be other arrangements whilst the batteries are recharging. Details of the testing and commissioning carried out on the emergency lighting system, including dates and the results of the tests. The name of the person or organization responsible for the maintenance and testing of the emergency lighting system.

Our pre-service audit enables us to design a comprehensive testing procedure for every building, allowing our testers to examine your system safely and successfully. This means we can test your emergency lighting systems and report with complete building knowledge, ensuring the service runs as smoothly as possible. Tenant Liaison Is your building permanently used E.G. Hotels, then you need to test the lights so that the end of the test corresponds to the start of day. In this way the emergency lights will have a good time to recharge during daylight hours. Natural daylight will help if the emergency lights don’t last 3 hours. Should I test ALL emergency lights at once?

Additional Combined Services

Confirmation that the emergency lighting system has been installed in accordance with the relevant regulations and standards. Testing involves simulated, circuit-by-circuit mains lighting systems failures. Using a ‘fishtail key’ is one way of conducting this testing. Annual testing requires three-hour load testing, including battery testing and maintenance. Once the mains failure simulation has taken place, lighting failures and issues need to be noted and a plan of action to rectify problems should be devised. Our experienced testers conduct over 14,000 emergency lighting tests every year in properties across the country. They test and inspect all units to ensure they’re functioning correctly.

Our experienced testers conduct over 14,000 emergency lighting tests every year in properties across the UK. They test and inspect all units to ensure they’re functioning correctly. Pre-service audit Now the refurbishment on the ground floor seems to be wired up in the 'new' way - does not extinguish power to mains. UK fire safety legislation states that emergency lighting is required in buildings to provide light if normal lighting fails during a fire. When zero voltage is detected at L PERM it is the indication to the emergency module in the light fitting that mains power has been lost and that battery power must now be switched on.

Tenant Liaison

Details of any repairs or replacements carried out on the emergency lighting system, including dates and the nature of the work carried out. UK fire regulations stipulate that your emergency lights should be turned on and off monthly to test them and have a full service once a year. The latest British Standard recommends that you have a 3 hour emergency lighting test once a year, during which your main light circuit should be switched off and your emergency lights left on for a 3 hour period to find out of any batteries need replacing. How can Equiptest help me? Self-test has several benefits. First, it saves the labour of manual testing. Secondly, it removes the risk that routine monthly or annual testing is overlooked. The needs of every building must be outlined in a fire risk assessment. This fire risk assessment needs to be reassessed every year to ensure it meets the changing needs of the premises. British Standards and Codes detail the nature and installation of emergency escape lighting systems. Yes if you are testing/servicing on the discharge test then no lights would be a problem for persons working in those areas and so this would need doing when unoccupied - so I can see the logic behind the key switches not shutting off power - but that would only be for green LEDs and not red LEDs that would be difficult to visually see - similar if 3 tube lighting is working and one of the tubes is the EL light you wouldn't know if that EL unit was working if the main lights are still being powered...

There are three widely used ways to test emergency lighting. To understand them it is necessary to understand first how an emergency light fitting is wired. Note that the remarks that follow apply to self-contained emergency fittings, not to central battery operated emergency fittings. There are different types of emergency lighting; it can be maintained, non-maintained, or combined. Often there are choices with how long they remain on after a power failure. Maintained Emergency Lighting This performs the same function as a key-switch, isolating the fitting from its permanent live supply and thereby simulating a power failure. Details of the emergency lighting system, including its location, components, and the type of system installed. We also offer a number of additional services which are available alongside our regular monthly emergency lighting or weekly fire alarm tests.This means that the emergency light fitting works with the main lights and is connected to the other lights and is controlled with the normal lighting. When the power fails, the emergency light remains on through the battery which has been charged whilst the mains is on. It can also be turned off whilst the mains is on if it is not needed. The battery often emits around 10% of the normal light levels. Non-Maintained Emergency Lighting If you have a central battery system, then most of the above still applies to you. Drop the incoming power to the battery and do the same walk tests. Make a note of any failures etc. However you need to test the whole system all at once. By testing the whole system at once, you are ensuring that the battery can power all the emergency lights for a full 3 hour duration. If you only tested in zones then the battery would not get a full and proper test. High risk task area lighting provides light for the safety of people involved in potentially dangerous processes. This lighting enables proper shut-down procedures to be followed for the safety of the operator and other occupants of a building. In my humble opinion the switch should be of "simulation" status IE cutting power (as it would if in a power cut, fire, etc.) and illuminating EL only.

Non-domestic properties have a statutory responsibility to supply, test, and maintain emergency lighting systems. The reason for the regulations is to promote safety should the power supply go down for any reason. In such an event, emergency lighting provides illumination for safe evacuation or manoeuvre around the building’s interior. It can also support operational continuity in some contexts. Simulate a power failure by either an emergency key switch or by switching off the mains power to the emergency lighting.The duration that emergency lighting should stay on for depends on the relevant regulations and standards, as well as the specific requirements of the building and its occupants. However, the general requirement is that emergency lighting should remain illuminated for a minimum of 1 hour, but it may need to remain illuminated for up to 3 hours in certain circumstances. Standby lighting enables normal activities within in building to continue in the event of a mains power failure. Standby lighting is not a legal requirement but is a facility that some buildings may need depending on the use and occupancy of the premises. L SW is the normal mains supply. A normal light switch, or sensor, would usually be on this circuit to enable the end-user to have control over the light fitting in normal operating mode. L SW is always to be wired so that any switching of L PERM will disconnect L SW too, but any switching of L SW will not affect L PERM. An emergency log book is required to keep a record of all the testing, maintenance, and servicing carried out on an emergency lighting system. It is a legal requirement to keep an emergency log book for each building that has an emergency lighting system installed.